top of page
Untitled design (4).png

WE ARE HERE

Discover our Generators

Cummins offers a complete range of CPCB IV+ compliant gensets from 7.5 kVA to 3750 kVA, designed to meet the latest emission norms without compromising on performance. Built for residential, commercial, and industrial use, these gensets combine fuel efficiency, reliability, and a strong commitment to a cleaner, greener future.

STANDOUT

Why Cummins Gensets

generator-hero.webp

Excellence

  • Better fuel efficiency

  • Better load taking capability

  • 100% quality checks before dispatch

  • Space saver through compact size  

8734_CPG_Osprey_Shot 6-lpr.webp

Dependability

  • 100-year legacy of reliability and dependability

  • Designed and tested for extreme altitudes and temperatures

  • Seamless transition from grid to genset

  • Expert guidance on installation

man-inspecting-generator-800.jpg

Innovation

  • Next-gen remote monitoring device

  • Advanced Engine Control Module

  • Fuel and DEF level sensor

  • Audio-visual alarm to indicate major faults

cummins-sales-service-worker.jpg

Service

  • 24*7 Pan-India service support

  • 4-hour service response guarantee

  • Mobile-friendly customer care app

  • Comprehensive 2-year warranty with additional 3-year 5C warranty

SEARCH

Find the right Genset for you

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 7.5D5P

7.5

16.8

3

415

X2.5-G5

S0L1-D

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 7.5D5SP

7.5

16.8

1

230

X2.5-G5

S0L1-J

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 10D5SP

10

16.8

1

230

X2.5-G5

S0L1-S

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 10D5P

10

16.8

3

415

X2.5-G5

S0L1-H

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 15D5P

15

25.2

3

415

X2.5-G6

S0L1-P

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 15D5SP

15

25.2

1

230

X2.5-G6

S0L2-K

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 18.5D5SP

18.5

25.2

1

230

X2.5-G6

S0L2-U

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 20D5P

20

25.2

3

415

X2.5-G6

S0L2-M

PS0600

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 25D5SP

25

41.2

1

230

X2.6-G1

S1L2-K

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 25D5P

25

41.2

3

415

X2.6-G1

S0L2-M

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 27.5D5SP

27.5

41.2

1

230

X2.6-G1

S1L2-R

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 30D5P

30

41.2

3

415

X2.6-G1

S0L2-P

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 35D5P

35

53.1

3

415

X2.6-G2

S1L2-J

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 35D5SP

35

53.1

1

230

X2.6-G2

S2L1D-E

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 40D5P

40

53.1

3

415

X2.6-G2

S2L1D-C4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 41D5SP

41

74.4

1

230

X3.6-G3

S2L1D-F

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 50D5SP

50

74.4

1

230

X3.6-G3

S2L1D-G

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 50D5P

50

74.4

3

415

X3.6-G3

S2L1D-D4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 58.5D5P

58.5

74.4

3

415

X3.6-G3

S2L1D-E4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 82.5D5P

82.5

132

3

415

QSB4.5-G1

S2L1D-G4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 100D5P

100

132

3

415

QSB4.5-G1

S3L1D-C4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 125D5P

125

161.6

3

415

QSB4.5-G2

S3L1D-D4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 140D5P

140

175.3

3

415

QSB4.5-G3

S3L1D-E4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 160D5P

160

206.8

3

415

QSB6.7-G21

S3L1D-F4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 180D5P

180

249.1

3

415

QSB6.7-G22

S3L1D-G4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 200D5P

200

249.1

3

415

QSB6.7-G22

S3L1D-H4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 225D5P

225

306.9

3

415

QSB6.7-G23

S3L1D-K4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 250D5P

250

306.9

3

415

QSB6.7-G23

S3L1D-K4

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 320D5P

320

395

3

415

QSL9-G20

HCI444D

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 380D5P

380

594

3

415

QSM15-G1

HCI444E

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 400D5P

400

594

3

415

QSM15-G1

HCI444F

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 500D5P

500

594

3

415

QSM15-G1

HCI544D

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 650D5P

650

888

3

415

QSK19-G30

HCI544F

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

CI 750D5P

750

888

3

415

QSK19-G30

HCI634W

PS0602

Yes

Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C750D5P

750

888

3

415

QSK19-G30

HCI634W

PS0602

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C1010D5P

1010

1180

3

415

KTA38-G19

HCI634Y

PS0601

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C1010D5P

1010

1180

3

415

KTA38-G19

HCKI634Z

PS0601

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C1250D5P

1250

1470

3

415

KTA50-G27

HCKI634Z

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C1250D5P

1250

1470

3

415

KTA50-G27

HC1634Z

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C1500D5P

1500

1735

3

415

KTA50-G8-I

S7L1D-C4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C1800D5P

1800

2101

3

415

KTA50-G22

S7L1D-F4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2000D5P

2000

2334

3

415

KTA50-G21

S7L1D-G4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2000D5P

2000

2319

3

415

QSK60-G4

S7L1D-G4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2200D5

2200

2567

3

415

QSK60-G4

S7L1D-H4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2250D5P

2250

2603

3

415

QSK60-G8

S7L1D-H4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2500D5P

2500

2893

3

415

QSK60-G23

LVS1804X

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2500D5

2500

2875

3

415

QSK60-G8

S7L1D-H4

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C3000D5

2750

3088

3

415

QSK78-G15

LVSI804T

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C2750D5

2750

3202

3

415

QSK60-G23

LVSI804X

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C3000D5

3000

3404

3

415

QSK78-G15

LVSI804T

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C3750D5

3350

3866

3

415

QSK95-G10

LVS1804X

PC3.3

No

Spec. Sheet/ Brochure
Untitled design (4).png

Model

kVA

BHP

Phase

Output Voltage

Engine Model

Alternator Frame

Genset Controller

CPCB IV+

C3750D5

3750

4351

3

415

QSK95-G10

LVSI804X

PC3.3

No

Spec. Sheet/ Brochure
bottom of page